📊 Home Energy DatasetVersion 1.1.0CC BY 4.0 Open AccessDOI: 10.6084/m9.figshare.33470950

Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset

Sub-freezing ambient temperature spectra (-20°C to +10°C) COP degradation, flash-injection capacity curves, and auxiliary resistive staging economics under AHRI 210/240.

Record Count240 Records
File Format & SizeCSV / Tabular Matrix (215 KB)
Published Date2026-08-28
Primary RepositoryFigshare
📥 Download CSV Dataset (Direct DOI)📄 Read Whitepaper (PL-TR-2026-HVAC01) →

1. Abstract & Dataset Scope

Provides empirical thermodynamic matrices measuring Coefficient of Performance (COP), delivered thermal capacity (BTU/hr and kW), and electrical input power across 240 ambient temperature and compressor modulation bins under AHRI 210/240-2023 and DOE Appendix M1 test conditions.

2. Experimental & Simulation Methodology

Calculated via thermodynamic vapor compression cycle modeling integrating empirical AHRI laboratory test points, defrost penalty multipliers, and variable-speed inverter vapor injection modulation curves.

Reproducibility Standard: All values are generated deterministically in compliance with applicable standards (NEC, IEEE, AHRI, NREL, ISO) and can be audited directly through our TypeScript engines.

3. Data Dictionary & Variable Definitions

Variable NameSymbolUnitTypeDescriptionExample
Outdoor Ambient TemperatureT_amb°F / °CFloatDry-bulb outdoor ambient temperature5
Coefficient of PerformanceCOPDimensionlessFloatRatio of delivered thermal heat energy to electrical power input2.15
Thermal Capacity RatioCap_ratio% of RatedFloatPercentage of nominal 47°F rated heating capacity maintained78.4
Electrical Power InputP_eleckWFloatCompressor and outdoor fan electrical demand3.42
Auxiliary Strip Heat ActiveAux_stateBooleanStringStatus of secondary electric resistance elementsFALSE
Operating Cost RateCost_hr$/HourFloatEstimated hourly running cost at $0.18/kWh baseline tariff0.62

4. Sample Data Records Preview

Displaying 6 representative rows (Full dataset contains 240 Records)
temp ftemp ccopcapacity pctpower kwaux engagedcost per hr
478.33.851002.74NO$0.49
351.73.1291.52.88NO$0.52
17-8.32.45823.28NO$0.59
5-152.0574.53.56NO$0.64
-5-20.51.7261.23.48YES (5kW)$1.53
-15-26.11.35483.5YES (10kW)$2.43

5. Dataset Citation (BibTeX / APA / IEEE)

When referencing this dataset in academic preprints, technical reports, or computational tooling, please cite using the standard DataCite DOI reference below:

APA Style

PowerLab Clean Energy Engineering Group. (2026). Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset (Version 1.1.0) [Data set]. Figshare. https://doi.org/10.6084/m9.figshare.33470950

IEEE Style

PowerLab Clean Energy Engineering Group, "Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset," Figshare, 2026, doi: 10.6084/m9.figshare.33470950.

BibTeX Record

@dataset{powerlab_2026_heatpump_dataset,
  author       = {{PowerLab Clean Energy Engineering Group}},
  title        = {Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset},
  year         = {2026},
  publisher    = {Figshare},
  version      = {1.1.0},
  doi          = {10.6084/m9.figshare.33470950},
  url          = {https://www.powelab.org/datasets/cold-climate-heat-pump-cop-degradation-benchmark}
}

6. Connected Calculators & Research Whitepapers

Companion Whitepaper (PL-TR-2026-HVAC01)

Thermal Degradation Kinetics, Auxiliary Electric Resistance Staging, and Seasonal HSPF2/COP Derating in Cold-Climate Air-Source Heat Pumps

Read Full Technical Report →
Interactive Calculation Engine

Heat Pump Running Cost Calculator

Open Computational Tool →
Interactive Calculation Engine

Air Conditioner Running Cost Calculator

Open Computational Tool →
Interactive Calculation Engine

Electricity Usage Calculator

Open Computational Tool →
Authoritative Engineering Guide

Central AC & Heat Pump Electricity Cost Guide

Read Technical Guide →
Authoritative Engineering Guide

Daily Household Electricity Consumption Guide

Read Technical Guide →