📊 Home Energy DatasetVersion 1.1.0CC BY 4.0 Open AccessDOI: 10.6084/m9.figshare.33470950↗

Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset

Sub-freezing ambient temperature spectra (-25°F to +65°F) COP degradation, sensible heating capacity retention, and auxiliary resistive staging economics referencing AHRI 210/240 performance test points.

Record Count20 Records
Format / SizeCSV / Tabular Matrix (2 KB)
Published Date2026-08-28
Primary RepositoryFigshare
📥 Download CSV Dataset📊 View on Figshare ↗📄 Read Whitepaper (PL-TR-2026-HVAC01) →

1. Abstract & Dataset Scope

Provides a source-informed deterministic benchmark matrix modeling heating Coefficient of Performance (COP), delivered thermal capacity, electrical input power, and electric resistance auxiliary staging across 20 ambient outdoor temperature points (-25°F to +65°F) under AHRI 210/240 and DOE Appendix M1 calculation principles.

2. Technical Methodology & Benchmark Formulation

Deterministic thermodynamic modeling incorporating empirical heating test point references (AHRI 210/240), frost accumulation and defrost cycle penalties, and compressor power draw scaling across a representative 3-ton nominal residential heat pump heating a standard residential building envelope.

Reproducibility Standard: All values are deterministically generated from the documented assumptions, equations, source references, and modeling parameters described on this page. The dataset is an engineering benchmark and does not constitute certified laboratory test data or certification to any referenced standard.

3. Data Dictionary & Variable Definitions

Variable NameSymbolUnitTypeDescriptionExample
Outdoor Ambient Temperature (°F)T_amb_f°FFloatDry-bulb outdoor ambient temperature in Fahrenheit5
Outdoor Ambient Temperature (°C)T_amb_c°CFloatDry-bulb outdoor ambient temperature in Celsius-15
Nominal Compressor COPCOP_nomDimensionlessFloatCarnot and inverter-modeled nominal heating efficiency ratio2.2
Defrost Penalty FactorK_defrostMultiplierFloatEfficiency derating factor during active or pending coil defrost1
Effective Compressor COPCOP_effDimensionlessFloatNet heating efficiency factoring defrost cycle overhead2.2
Capacity RetentionCap_ret_pct% of 47°FFloatAvailable sensible heat output relative to nominal rating76
Delivered Heating OutputQ_heatBTU/hrFloatTotal sensible heat energy supplied to the conditioned space27360
Building Heat LossQ_lossBTU/hrFloatEstimated building heat transmission demand at target outdoor temperature32500
Thermal DeficitQ_deficitBTU/hrFloatUnmet heating demand requiring auxiliary staging5140
Auxiliary Resistance HeatP_auxkWFloatEngaged electric resistance strip element heating power1.51
Compressor Power DrawP_compkWFloatElectrical input power demand of the inverter compressor3.64
Total Electrical LoadP_totalkWFloatCombined electrical power draw (compressor + auxiliary strips)5.15
Combined System COPCOP_sysDimensionlessFloatOverall heating efficiency including strip heat contribution1.85

4. Sample Data Records Preview

Displaying 6 representative rows (Full dataset contains 20 Records)
temp ftemp ccop nominaldefrost factoreffective copcapacity retention pctdelivered heat btuaux heat kwtotal load kwsystem cop
478.34.7214.721003600000.714.72
351.73.970.9033.581003250801.433.58
17-8.32.740.9852.7983474902.992.7
5-152.212.276273601.515.151.85
-5-20.61.7411.7458208804.878.391.31
-15-26.11.3611.3644158407.8111.221.11

5. Limitations & Engineering Disclaimer

This dataset provides modeled engineering benchmarks and reference calculations. It is not certified laboratory test data, does not represent specific manufacturer equipment performance, does not constitute AHRI or ENERGY STAR compliance certification, and does not replace professional HVAC Manual J/S sizing or manufacturer engineering specifications.

Jurisdictional Notice: Model codes become legally enforceable when adopted or incorporated by the applicable jurisdiction, including applicable local amendments. System designers and installers must consult the requirements adopted by the applicable Authority Having Jurisdiction (AHJ) and current manufacturer technical specifications.

6. Dataset Citation (BibTeX / APA / IEEE)

When referencing this dataset in academic preprints, technical reports, or computational tooling, please cite using the formal reference metadata below:

APA Style

Miad S., & PowerLab Clean Energy Engineering Group. (2026). Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset (Version 1.1.0) [Data set]. Figshare. https://doi.org/10.6084/m9.figshare.33470950

IEEE Style

Miad S. and PowerLab Clean Energy Engineering Group, "Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset," Figshare, 2026, doi: 10.6084/m9.figshare.33470950.

BibTeX Record

@dataset{powerlab_2026_heatpump_dataset,
  author       = {Miad S. and {PowerLab Clean Energy Engineering Group}},
  title        = {Cold-Climate Air-Source Heat Pump COP Degradation & Balance Point Dataset},
  year         = {2026},
  publisher    = {Figshare},
  version      = {1.1.0},
  doi          = {10.6084/m9.figshare.33470950},
  url          = {https://www.powelab.org/datasets/cold-climate-heat-pump-cop-degradation-benchmark}
}

7. Connected Calculators & Research Whitepapers

Companion Whitepaper (PL-TR-2026-HVAC01)

Thermal Degradation Kinetics, Auxiliary Electric Resistance Staging, and Seasonal HSPF2/COP Derating in Cold-Climate Air-Source Heat Pumps

Read Full Technical Report →
Interactive Calculation Engine

Heat Pump Running Cost Calculator

Open Computational Tool →
Interactive Calculation Engine

Air Conditioner Running Cost Calculator

Open Computational Tool →
Interactive Calculation Engine

Electricity Usage Calculator

Open Computational Tool →
Technical Engineering Guide

Central AC & Heat Pump Electricity Cost Guide

Read Technical Guide →
Technical Engineering Guide

Daily Household Electricity Consumption Guide

Read Technical Guide →