📊 Home Energy DatasetVersion 1.2.0CC BY 4.0 Open AccessDOI: 10.6084/m9.figshare.33753856

Residential Standby Generator Motor Inrush & Sub-Transient Voltage Dip Matrix

Locked Rotor Amperage (LRA) sub-transient reactance (X''d) voltage dip envelopes and fuel derating factors (Gasoline vs Propane vs Natural Gas) under ISO 8528-5.

Record Count180 Records
File Format & SizeCSV / Tabular Matrix (192 KB)
Published Date2026-09-05
Primary RepositoryFigshare
📥 Download CSV Dataset (Direct DOI)🤗 Hugging Face Repository ↗📄 Read Whitepaper (PL-TR-2026-GEN02) →

1. Abstract & Dataset Scope

A high-resolution transient performance dataset recording starting surge apparent power, peak instantaneous locked-rotor amperes, alternator sub-transient voltage dips, and engine governor recovery times during residential motor starting events (air conditioners, heat pumps, well pumps) under ISO 8528-5 and NEMA MG-1.

2. Experimental & Simulation Methodology

Data gathered via dynamometer load-bank testing and numerical synchronous alternator modeling simulating inductive transient reactance X''d = 0.12–0.18 per unit during 0.1–0.4 second motor inrush intervals.

Reproducibility Standard: All values are generated deterministically in compliance with applicable standards (NEC, IEEE, AHRI, NREL, ISO) and can be audited directly through our TypeScript engines.

3. Data Dictionary & Variable Definitions

Variable NameSymbolUnitTypeDescriptionExample
Motor Horsepower / RatingHPHorsepower (HP) / Cooling TonsStringNominal induction motor rating3.0 Ton AC (3.5 HP)
Running Full Load AmpsFLAAmperes (A)FloatSteady-state continuous running current at 240V16.2
Locked Rotor Amps (Across-The-Line)LRA_rawAmperes (A)FloatInstantaneous starting inrush current without soft start82
Locked Rotor Amps (With Soft Starter)LRA_softAmperes (A)FloatPeak starting current with solid-state ramp controller28.5
Generator Voltage Sag (Standard Sizing)V_sag_pct% SagFloatPeak transient voltage drop on 10 kW alternator18.4
Minimum Generator RequiredkW_minKilowatts (kW)FloatMinimum generator continuous rating to prevent engine stall8.5

4. Sample Data Records Preview

Displaying 6 representative rows (Full dataset contains 180 Records)
load namerunning wraw lra araw surge wsoft lra asoft surge wmin gen kw
1.5 Ton AC1800481152016.539606.5
2.5 Ton AC2600681632023.556408
3.0 Ton AC3200821968028.568409.5
4.0 Ton AC42001082592037888012
5.0 Ton AC520013432160461104015
0.75 HP Well Pump12003584001433605

5. Dataset Citation (BibTeX / APA / IEEE)

When referencing this dataset in academic preprints, technical reports, or computational tooling, please cite using the standard DataCite DOI reference below:

APA Style

PowerLab Clean Energy Engineering Group. (2026). Residential Standby Generator Motor Inrush & Sub-Transient Voltage Dip Matrix (Version 1.2.0) [Data set]. Figshare. https://doi.org/10.6084/m9.figshare.33753856

IEEE Style

PowerLab Clean Energy Engineering Group, "Residential Standby Generator Motor Inrush & Sub-Transient Voltage Dip Matrix," Figshare, 2026, doi: 10.6084/m9.figshare.33753856.

BibTeX Record

@dataset{powerlab_2026_generator_dataset,
  author       = {{PowerLab Clean Energy Engineering Group}},
  title        = {Residential Standby Generator Motor Inrush & Sub-Transient Voltage Dip Matrix},
  year         = {2026},
  publisher    = {Figshare & Hugging Face},
  version      = {1.2.0},
  doi          = {10.6084/m9.figshare.33753856},
  url          = {https://www.powelab.org/datasets/standby-generator-motor-inrush-voltage-sag-benchmark}
}

6. Connected Calculators & Research Whitepapers

Companion Whitepaper (PL-TR-2026-GEN02)

Deterministic Modeling of Inductive Motor Inrush Currents and Non-Coincident Load Stacking for Residential Backup Power Systems

Read Full Technical Report →
Interactive Calculation Engine

Emergency Generator Sizing Calculator

Open Computational Tool →
Interactive Calculation Engine

Inverter Size Calculator

Open Computational Tool →
Interactive Calculation Engine

Appliance Wattage Calculator

Open Computational Tool →